E-mail:info@comilandscapelighting.com TEL:+86-755-23158250

COMI Lighting Limited

About IP Code and IK Code

Source of articles: COMI Lighting Limited Popularity:1979 Publication time:2018-12-13 23:33:22 small middle big

IP Code:


The IP CodeInternational Protection Marking, IEC standard 60529, sometimes interpreted as Ingress Protection Marking, classifies and rates the degree of protection provided against intrusion (body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The equivalent European standard is EN 60529.

The standard aims to provide users more detailed information than vague marketing terms such as waterproof. For example, a cellular phone rated at IP68 is "dust resistant" and can be "immersed in 1.5 meters of freshwater for up to 30 minutes". Similarly, an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. IP22 or IP2X are typical minimum requirements for the design of electrical accessories for indoor use.

The digits indicate conformity with the conditions summarized in the tables below. The digit 0 is used where no protection is provided. The digit is replaced with the letter X when insufficient data has been gathered to assign a protection level.

There are no hyphens in a genuine IP code. IPX-8 (for example) is thus an invalid IP code.[1]

This page contains a combination of IEC 60529 (also EN 60529) and other standards, such as ISO 20653. The original documents are available for purchase, and have important and specific requirements that cannot be fully reprinted due to copyright restrictions. This often includes drawings specifying the required test equipment, such as the shape of water nozzles used for water jet testing. Additional standards are often referenced that may contain important information. One must refer to the latest revision of the required standard when conducting tests for agency certification.



This table shows what each digit or part of the IP code represents.

IPX Codes Explanation Chart
IP indication First digit: Solid particle protection Second digit: Liquid ingress protection Third digit: Mechanical impact resistance Additional letter: Other protections
IP Single numeral: 0–6 Single numeral: 0–9 Single numeral: 0–9 Single letter
Mandatory Mandatory Mandatory No longer used Optional

First digit: Solid particle protection[edit]

The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.[2]

Level sized Effective against Description
X X means there is no data available to specify a protection rating with regard to one of the criteria.
0 No protection against contact and ingress of objects
1 >50 mm Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
2 >12.5 mm Fingers or similar objects
3 >2.5 mm Tools, thick wires, etc.
4 >1 mm Most wires, slender screws, large ants etc.
5 Dust protected Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment.
6 Dust tight No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow.

Second digit: Liquid ingress protection[edit]

The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.[3] The ratings for water ingress are not cumulative beyond IPX6. A device which is compliant with IPX7, covering immersion in water, need not be compliant with IPX5 or IPX6, covering exposure to water jets. A device which meets both tests is indicated by listing both tests separated by a slash, e.g. IPX5/IPX7.

Level Protection against Effective against Details
0 None
1 Dripping water Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. Test duration: 10 minutes 

Water equivalent to 1 mm rainfall per minute

2 Dripping water when tilted at 15° Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. Test duration: 2.5 minutes for every direction of tilt (10 minutes total)

Water equivalent to 3 mm rainfall per minute

3 Spraying water Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.

Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum.

For a Spray Nozzle:

Test duration: 1 minute per square meter for at least 5 minutes[4]
Water volume: 10 litres per minute
Pressure: 50–150 kPa

For an oscillating tube:

Test duration: 10 minutes

Water Volume: 0.07 l/min per hole

4 Splashing of water Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.

Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum.

Oscillating tube: Test duration: 10 minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed)
5 Water jets Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects. Test duration: 1 minute per square meter for at least 15 minutes

Water volume: 12.5 litres per minute
Pressure: 30 kPa at distance of 3 m

6 Powerful water jets Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. Test duration: 1 minute per square meter for at least 3 minutes

Water volume: 100 litres per minute
Pressure: 100 kPa at distance of 3 m

6K Powerful water jets with increased pressure Water projected in powerful jets (6.3 mm nozzle) against the enclosure from any direction, under elevated pressure, shall have no harmful effects. Found in DIN 40050, and not IEC 60529. Test duration: at least 3 minutes[citation needed]

Water volume: 75 litres per minute
Pressure: 1000 kPa at distance of 3 m

7 Immersion, up to 1 m depth Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). Test duration: 30 minutes - ref IEC 60529, table 8.

Tested with the lowest point of the enclosure 1000 mm below the surface of the water, or the highest point 150 mm below the surface, whichever is deeper.

8 Immersion, 1 m or more depth The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. The test depth and duration is expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion. Test duration: Agreement with Manufacturer

Depth specified by manufacturer, generally up to 3 m

9K Powerful high temperature water jets Protected against close-range high pressure, high temperature spray downs.

Smaller specimens rotate slowly on a turntable, from 4 specific angles. Larger specimens are mounted upright, no turntable required, and are tested freehand for at least 3 minutes at distance of 0.15–0.2 m.

There are specific requirements for the nozzle used for the testing.

This test is identified as IPx9 in IEC 60529.

Test duration: 30 seconds in each of 4 angles (2 minutes total)

Water volume: 14–16 litres per minute
Pressure: 8–10 MPa (80–100 bar) at distance of 0.10–0.15 m
Water temperature: 80 °C

(All tests with the letter "K" are defined by ISO 20653 (replacing DIN 40050-9) and are not found in IEC 60529, except for IPx9 which is the same as the IP69K water test.)


IK Code:



The European standard EN 62262 — the equivalent of international standard IEC 62262 (2002) — relates to IK ratings. This is an international numeric classification for the degrees of protection provided by enclosures for electrical equipment against external mechanical impacts. It provides a means of specifying the capacity of an enclosure to protect its contents from external impacts. The IK Code was originally defined in European Standard BS EN 50102 (1995, amended 1998). Following its adoption as an international standard in 2002, the European standard was renumbered EN 62262.

Before the advent of the IK code, a third numeral had been occasionally added to the closely related IP Code on ingress protection, to indicate the level of impact protection — e.g. IP66(9). Nonstandard use of this system was one of the factors leading to the development of this standard, which uses a separate two numeral code to distinguish it from the old differing systems. The standard came into effect in October 1995 and conflicting national standards had to be withdrawn by April 1997.

IK ratings help to classify products by its resistance to impacts by Kinetic energy, while EN 62262 specifies the way enclosures should be mounted when tests are carried out, the atmospheric conditions that should prevail, the number of impacts (5) and their (even) distribution, and the size, style, material, dimensions etc. of the various types of hammer designed to produce the energy levels required.

IK code and impact energy (values changed in Amd 1:1998)
IK code IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10
Impact energy (joule) * 0.14 0.2 0.35 0.5 0.7 1 2 5 10 20
Impact test characteristics
IK code IK00 IK01 to IK05 IK06 IK07 IK08 IK09 IK10
Impact energy (joules) * <1 1 2 5 10 20
R mm (radius of striking element) * 10 10 25 25 50 50
Material * polyamide1 polyamide1 steel2 steel2 steel2 steel2
Mass kg * 0.2 0.5 0.5 1.7 5 5
Pendulum hammer * Yes Yes Yes Yes Yes Yes
Spring hammer * Yes Yes Yes No No No
Free fall hammer * No No Yes Yes Yes Yes

* not protected according to the standard

  1. HR 100 Rockwell hardness according to ISO 2039/2